{"id":1200,"date":"2024-09-12T11:56:47","date_gmt":"2024-09-12T03:56:47","guid":{"rendered":"https:\/\/en.zwinsoft.com\/?p=1200"},"modified":"2024-09-12T11:56:47","modified_gmt":"2024-09-12T03:56:47","slug":"water-quality-monitoring-sensor-series-products-part-one","status":"publish","type":"post","link":"https:\/\/en.zwinsoft.com\/?p=1200","title":{"rendered":"Water Quality Monitoring Sensor Series Products (Part One)"},"content":{"rendered":"<p><strong><b>Digital PH Sensor-ZW-PH1006<\/b><\/strong><\/p>\n<p style=\"text-align: center;\"><strong><b>\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-1201\" src=\"https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72471-1.png\" alt=\"\" width=\"78\" height=\"368\" \/><\/b><\/strong><\/p>\n<p><strong><b>Product introduction: \u00a0\u00a0\u00a0\u00a0\u00a0<\/b><\/strong><\/p>\n<p>The digital pH sensor is used to accurately measure the pH value of the solution, that is, the acidity and alkalinity of the solution. It is based on a glass electrode and can provide accurate pH measurement, usually with an accuracy of \u00b10.01pH unit. The sensor outputs a digital signal and has a built-in temperature sensor with good stability and repeatability.<\/p>\n<p><strong><b>Application areas:<\/b><\/strong><\/p>\n<p>Aquaculture water bodies, drinking water sources, sewage treatment plant treatment process and discharge port water quality monitoring, industrial process water quality monitoring, surface water\/groundwater monitoring, other industrial wastewater treatment process and discharge port monitoring installations, etc.<\/p>\n<p><strong><b>Performance parameters:<\/b><\/strong><\/p>\n<p>\u2b50Measurement principle: glass electrode method;<\/p>\n<p>\u2b50Measuring range: 0~14PH;<\/p>\n<p>\u2b50Accuracy: &lt;0.1PH;<\/p>\n<p>\u2b50Resolution: 0.01PH;<\/p>\n<p>\u2b50Repetition rate: &lt;0.1PH;<\/p>\n<p>\u2b50Drift: &lt;0.3PH;<\/p>\n<p>\u2b50Temperature compensator error: &lt;0.1PH;<\/p>\n<p>\u2b50Response time: &lt;15s;<\/p>\n<p>\u2b50Working temperature: 0-50\u2103;<\/p>\n<p>\u2b50Sensor size (DxL): \u03a634X225;<\/p>\n<p>\u2b50Shell material: POM;<\/p>\n<p>\u2b50Protection level: IP68, 6bar.<\/p>\n<p><strong><b>Digital Dissolved Oxygen Sensor-ZW-D01006<\/b><\/strong><\/p>\n<p style=\"text-align: center;\"><strong><b><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-1202\" src=\"https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72472.png\" alt=\"\" width=\"86\" height=\"407\" \/>\u00a0<\/b><\/strong><\/p>\n<p><strong><b>Product introduction\uff1a<\/b><\/strong><\/p>\n<p>The digital dissolved oxygen sensor is an instrument used to measure the dissolved oxygen content in water samples. It is based on electrochemical principle and uses platinum electrodes for the reduction reaction of oxygen molecules. The concentration of dissolved oxygen is determined by measuring the current generated when oxygen molecules undergo reduction reaction on the electrode surface.<\/p>\n<p><strong><b>Application areas<\/b><\/strong><strong><b>: <\/b><\/strong><\/p>\n<p>Widely used in sewage treatment process monitoring, environmental monitoring, aquaculture, scientific research and other fields.<\/p>\n<p><strong><b>Performance parameters\uff1a<\/b><\/strong><\/p>\n<p>\u2b50Measurement principle: fluorescence method;<\/p>\n<p>\u2b50Measuring range: 0~50mg\/L (ppm);<\/p>\n<p>\u2b50Accuracy: 0-100% &lt;\u00b11%;100-200% &lt;\u00b12%;&gt;200% (20-50ppm): 2~15%;<\/p>\n<p>\u2b50Resolution: 0.01mg\/L;<\/p>\n<p>\u2b50Repetition rate: &lt;0.3mg\/L;<\/p>\n<p>\u2b50Drift: &lt;0.3mg\/L;<\/p>\n<p>\u2b50Temperature compensator error: &lt;0.3mg\/L;<\/p>\n<p>\u2b50Response time: &lt;45s;<\/p>\n<p>\u2b50Working temperature: 0-50\u2103;<\/p>\n<p>\u2b50Working atmospheric pressure: 40-115 kPa ;<\/p>\n<p>\u2b50Sensor size (DxL): \u03a634X225;<\/p>\n<p>\u2b50Shell material: POM;<\/p>\n<p>\u2b50Protection level: IP68.6bar.<\/p>\n<p><strong><b>Digital <\/b><\/strong><strong><b>C<\/b><\/strong><strong><b>onductivity <\/b><\/strong><strong><b>S<\/b><\/strong><strong><b>ensor-ZW-Cond1006<\/b><\/strong><\/p>\n<p style=\"text-align: center;\"><strong><b> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-1203\" src=\"https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72473.png\" alt=\"\" width=\"81\" height=\"386\" srcset=\"https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72473.png 103w, https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72473-63x300.png 63w\" sizes=\"auto, (max-width: 81px) 100vw, 81px\" \/>\u00a0<\/b><\/strong><\/p>\n<p><strong><b>Product <\/b><\/strong><strong><b>i<\/b><\/strong><strong><b>ntroduction<\/b><\/strong><strong><b>\uff1a<\/b><\/strong><\/p>\n<p>The digital conductivity sensor is an instrument used to measure the conductivity in a solution or water, based on the conductivity of ions in the solution. When current passes through a solution containing ions, the movement of ions produces conductivity. The conductivity is proportional to the concentration and type of ions in the solution. The built-in temperature sensor automatically adjusts the measurement results to compensate for the effect of temperature on conductivity.<\/p>\n<p><strong><b>Application areas:<\/b><\/strong><\/p>\n<p>Widely used in fresh water monitoring, industrial heating\/cooling, drinking water quality analysis, water treatment, chemical industry, food processing, environmental monitoring and other fields.<\/p>\n<p><strong><b>Performance parameters<\/b><\/strong><strong><b>\uff1a<\/b><\/strong><\/p>\n<p>\u2b50Measurement principle: quadrupole conductivity;<\/p>\n<p>\u2b50Measuring range: 1\u03bcS\/cm-100mS\/cm or 1\u03bcS\/cm-200mS\/cm:<\/p>\n<p>\u2b50Accuracy: &lt; 1%;<\/p>\n<p>\u2b50Resolution: 0.01\/0.1\/1\u03bcS\/cm (depending on the range);<\/p>\n<p>\u2b50Repetition rate: &lt;1%;<\/p>\n<p>\u2b50Drift: &lt;1%;<\/p>\n<p>\u2b50Temperature compensator error: &lt;1%;<\/p>\n<p>\u2b50Response time: 10s;<\/p>\n<p>\u2b50Working temperature: 0-50\u2103<\/p>\n<p>\u2b50Sensor size (DxL): \u03a634X225;<\/p>\n<p>\u2b50Housing material: POM;<\/p>\n<p>\u2b50Protection level: IP68, 6bar.<\/p>\n<p><strong><b>Digital Turbidity Sensor-ZW-Turb1006<\/b><\/strong><\/p>\n<p style=\"text-align: center;\"><strong><b> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-1204\" src=\"https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72474.png\" alt=\"\" width=\"55\" height=\"329\" srcset=\"https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72474.png 75w, https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72474-50x300.png 50w\" sizes=\"auto, (max-width: 55px) 100vw, 55px\" \/>\u00a0<\/b><\/strong><\/p>\n<p><strong><b>Product <\/b><\/strong><strong><b>i<\/b><\/strong><strong><b>ntroduction<\/b><\/strong><strong><b>\uff1a<\/b><\/strong><\/p>\n<p>The digital turbidity sensor is an instrument used to measure the concentration of suspended particles in water samples. Usually these particles may be composed of sediment, microorganisms, algae or other organic or inorganic substances, which affect the transparency of water. It works based on the principle of light scattering. The sensor emits light through the water sample, and the suspended particles in the water sample scatter the light. By measuring the intensity of the scattered light, the turbidity of the water sample can be calculated.<\/p>\n<p><strong><b>Application areas:<\/b><\/strong><\/p>\n<p>Used in water quality monitoring, water treatment, food processing, environmental monitoring and other fields.<\/p>\n<p><strong><b>Performance parameters<\/b><\/strong><strong><b>\uff1a<\/b><\/strong><\/p>\n<p>\u2b50Measurement principle: scattering method;<\/p>\n<p>\u2b50Measuring range: turbidity: 0~4000NTU;<\/p>\n<p>\u2b50Suspended solids (SS): 0~8000mg\/L;<\/p>\n<p>\u2b50Accuracy:: &lt;5%;<\/p>\n<p>\u2b50Resolution: 0.01NTU; 0.01mg\/L;<\/p>\n<p>\u2b50Repetition rate: &lt;0.1NTU;<\/p>\n<p>\u2b50Drift: &lt;0.3NTU;<\/p>\n<p>\u2b50Temperature compensator error: &lt; 0.1NTU;<\/p>\n<p>\u2b50Response time: &lt;15s;<\/p>\n<p>\u2b50Working temperature: 0-50\u2103;<\/p>\n<p>\u2b50Sensor size (DxL): \u044434X225;<\/p>\n<p>\u2b50Housing material: titanium alloy;<\/p>\n<p>\u2b50Protection level: IP68, 6bar.<\/p>\n<p><strong><b>ZW-COD1006<\/b><\/strong><strong><b>\u00a0<\/b><\/strong><strong><b>UV254 COD\/TOC Sensor<\/b><\/strong><\/p>\n<p style=\"text-align: center;\"><strong><b><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-1205\" src=\"https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72475.png\" alt=\"\" width=\"378\" height=\"137\" srcset=\"https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72475.png 495w, https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72475-300x108.png 300w\" sizes=\"auto, (max-width: 378px) 100vw, 378px\" \/>\u00a0<\/b><\/strong><\/p>\n<p><strong><b>Product <\/b><\/strong><strong><b>i<\/b><\/strong><strong><b>ntroduction<\/b><\/strong><strong><b>\uff1a<\/b><\/strong><\/p>\n<p>Many organic substances dissolved in water have an absorption effect on external light. Therefore, by measuring the degree of absorption of these organic substances to 254nm wavelength ultraviolet light, the total amount of organic pollutants in the water can be measured. The UV254COD\/TOC online analyzer uses two light sources, one 254nm ultraviolet light and one 365nm reference light, which can automatically compensate for the attenuation of the light path and the influence of turbidity, thereby achieving more stable and reliable measurement values.<\/p>\n<p><strong><b>Performance parameters<\/b><\/strong><strong><b>\uff1a<\/b><\/strong><\/p>\n<p>\u2b50Measurement principle: dual beam absorbance method:254nm (COD detection);365nm reference light (eliminating the interference of suspended matter);<\/p>\n<p>\u2b50Measurement parameters: Simultaneous measurement of CODCr, TOC, turbidity and temperature; BOD, CODMn and other parameters can be converted;<\/p>\n<p>\u2b50Measurement optical path: 6mm or 1mm;<\/p>\n<p>\u2b50Range (6mm): CODcr: 0-500mg\/L;\u00a0TOC: 0-250 mg\/L (both using potassium hydrogen phthalate solution, KHP); turbidity: 0-500NTU;<\/p>\n<p>\u2b50Range (1mm): CODcr: 0-3000mg\/L; TOC: 0-1500 mg\/L4 (both using potassium hydrogen phthalate solution, KHP); turbidity: 0-3000NTU;<\/p>\n<p>\u2b50Accuracy: CODCr and TOC are both 5%; turbidity accuracy is 3%;<\/p>\n<p>\u2b50Resolution: CODCr is 0.01mg\/L; TOC is 0.1mg\/L;Turbidity resolution is 0.1NTU;<\/p>\n<p>\u2b50Response time: 1s;<\/p>\n<p>\u2b50Light window cleaning method: automatic cleaning with standard cleaning brush;<\/p>\n<p>\u2b50Sensor compensation: supports automatic compensation of temperature and turbidity;<\/p>\n<p>\u2b50Temperature application range: 0-45\u2103;<\/p>\n<p>\u2b50Protection level: IP68;\u00a0Maximum pressure: 1 bar;<\/p>\n<p>\u2b50Calibration method: 1 or 2 points;<\/p>\n<p>\u2b50Communication method: RS485 (Modbus RTU);<\/p>\n<p>\u2b50Power supply voltage: 12V DC+5%;<\/p>\n<p>\u2b50Power consumption: \u22640.6W (when not cleaning);<\/p>\n<p>\u2b50Cable length: 10m (customizable);<\/p>\n<p>\u2b50Housing material: POM and stainless steel 316L;<\/p>\n<p>\u2b50Installation method: immersion installation;<\/p>\n<p>\u2b50Probe size (DxL): \u03c650mmx214mm.<\/p>\n<p><strong><b>Digital Ammonia Nitrogen Sensor-ZW-NH3-N1006<\/b><\/strong><\/p>\n<p style=\"text-align: center;\"><strong><b> <img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-1206\" src=\"https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72476.png\" alt=\"\" width=\"79\" height=\"279\" srcset=\"https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72476.png 115w, https:\/\/en.zwinsoft.com\/wp-content\/uploads\/2024\/09\/\u56fe\u72476-85x300.png 85w\" sizes=\"auto, (max-width: 79px) 100vw, 79px\" \/><\/b><\/strong><\/p>\n<p><strong><b>Product <\/b><\/strong><strong><b>i<\/b><\/strong><strong><b>ntroduction<\/b><\/strong><strong><b>:<\/b><\/strong><\/p>\n<p>The ammonia nitrogen sensor uses an ion-selective electrode and has a membrane with a specific type of ion permeability. The composite sensor composed of this selective membrane and electrolyte can be used to measure the redox potential of the required specific ions (for example, NH4+).<\/p>\n<p><strong><b>Application areas<\/b><\/strong>:<\/p>\n<p>Sewage treatment plant treatment process and discharge port water quality monitoring, industrial process water quality monitoring, surface water\/groundwater monitoring, other industrial wastewater treatment process and discharge port monitoring installations, etc.<\/p>\n<p><strong><b>Performance parameters<\/b><\/strong><strong><b>:<\/b><\/strong><\/p>\n<p>\u2b50Measurement principle: ion selective electrode method;<\/p>\n<p>\u2b50Measuring range: 0.1~100mg\/L;<\/p>\n<p>\u2b50Accuracy: \u226410% of the measured value or 0.1mg\/L, whichever is greater;<\/p>\n<p>\u2b50Resolution: 0.1mg\/L;<\/p>\n<p>\u2b50Repetition rate: &lt;0.1mg\/L;<\/p>\n<p>\u2b50Drift: &lt;0.3mg\/L;<\/p>\n<p>\u2b50Temperature compensator error: &lt;0.1mg\/L;<\/p>\n<p>\u2b50Response time: &lt;15s;<\/p>\n<p>\u2b50Working temperature: 0-50\u2103;<\/p>\n<p>\u2b50Sensor size (DxL): \u044434X225;<\/p>\n<p>\u2b50Housing material: POM;<\/p>\n<p>\u2b50Protection level: IP68, 6bar.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Digital PH Sensor-ZW-PH1006 \u00a0 Product introduction: \u00a0\u00a0\u00a0\u00a0\u00a0 The digital pH sensor is used to accurately measure the pH value of the solution, that is, the acidity and alkalinity of the solution. It is based on a glass electrode and can provide accurate pH measurement, usually with an accuracy of \u00b10.01pH unit. The sensor outputs a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1207,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[5,9],"tags":[74,61],"class_list":["post-1200","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-product","category-water-quality","tag-real-time-monitoring","tag-water-quality"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/en.zwinsoft.com\/index.php?rest_route=\/wp\/v2\/posts\/1200","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/en.zwinsoft.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/en.zwinsoft.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/en.zwinsoft.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/en.zwinsoft.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1200"}],"version-history":[{"count":1,"href":"https:\/\/en.zwinsoft.com\/index.php?rest_route=\/wp\/v2\/posts\/1200\/revisions"}],"predecessor-version":[{"id":1208,"href":"https:\/\/en.zwinsoft.com\/index.php?rest_route=\/wp\/v2\/posts\/1200\/revisions\/1208"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/en.zwinsoft.com\/index.php?rest_route=\/wp\/v2\/media\/1207"}],"wp:attachment":[{"href":"https:\/\/en.zwinsoft.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1200"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/en.zwinsoft.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1200"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/en.zwinsoft.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1200"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}